1. Before the PET preform is injected, the material needs to be dried for three or four hours to prevent the moisture in the pet from exceeding the limit and affecting the quality of the product.
2. The template and mold of the injection molding machine will need to be separated by a heat shield, and there should be sufficient exhaust during injection molding to prevent the pet preform from breaking.
3. The melt temperature is controlled at 270-295°C, and the air injection method can be used for measurement when the pet preform is injected. the
4. The injection time of pet preforms should be fast, and the time can be controlled within four seconds. the
5. The back pressure is lower than 100bar to prevent wear and tear during the injection molding of pet preforms.
6. The residence time should not be too long. Generally, if the shutdown time does not exceed 15 minutes, it only needs to be treated by air injection, and if it exceeds, the viscosity PE can be used for cleaning.
Injection molding points of plastic preform production plant
1. Injection speed
Generally, the injection speed should be fast to avoid premature coagulation during injection. But too fast, the high shear rate makes the material brittle. The injection is generally completed within 4 seconds.
2. Stay time
Do not use excessively long residence times to avoid molecular weight loss. Try to avoid temperatures above 300°C. If the downtime is less than 15 minutes. It only needs to be treated with air injection; if it exceeds 15 minutes, it should be cleaned with viscosity PE, and the temperature of the barrel should be lowered to PE temperature until it is turned on again.
3. Selection of injection molding machine
Due to the short time for PET to stabilize after the melting point and the high melting point, it is necessary to use an injection system with more temperature control sections and less self-friction heat generation during plasticization, and the actual weight of the product (water-containing material) should not be less than machine injection. 2/3 of the amount.
4. Back pressure
The lower the better to avoid wear and tear. Generally not more than 100bar. Generally do not need to use.

38MM 3start PET Preform
NECK TYPE WEIGHT QTY/CTN CARTON SIZE
38mm 3start PET preform 16g 768 50x38x28
38mm 3start PET preform 18g 768 50x38x28
38mm 3start PET preform 20g 729 50x38x28
38mm 3start PET preform 25g 603 50x38x28
38mm 3start PET preform 28g 486 50x38x28
38mm 3start PET preform 30g 486 50x38x28
38mm 3start PET preform 38g 384 50x38x28
38mm 3start PET preform 42g 384 50x38x28
38mm 3start PET preform 46g 384 47x31x34
38mm 3start PET preform 50g 288 47x31x34
38mm 3start PET preform 52g 288 47x31x34
38mm 3start PET preform 59g 240 47x31x34
38mm 3start PET preform 64g 240 47x31x34
38mm 3start PET preform 70g 230 53x33x33
38mm 3start PET preform 72g 230 47x31x34
38mm 3start PET preform 73g 230 53x33x33
38mm 3start PET preform 75g 200 53x33x33
38mm 3start PET preform 77g 200 47x31x34
38mm 3start PET preform 80g 180 53x33x33
38mm 3start PET preform 85g 180 53x33x33
38mm 3start PET preform 90g 160 53x33x33

Contact Us